Heat pump. HSPF2 is the total space heating required over a heating season in the rating's reference climate (Region IV), in Btu, divided by the electricity the heat pump system uses in that season, in watt-hours. Applied to your home, the watt-hours needed are your heating need in Btu divided by the HSPF2, and the kilowatt-hours are that number divided by 1,000. The cost is kilowatt-hours times your electricity price.
Gas furnace. AFUE is the share of the fuel's heat that becomes space heat. So the gas burned, in Btu, is your heating need divided by the AFUE. To turn Btu into thousand cubic feet (Mcf) of gas, we divide by 1,037 Btu per cubic foot times 1,000 cubic feet. That is EIA's 2025 U.S. average heat content for natural gas delivered to end users. The cost is Mcf times your gas price.
Seasonal COP. ENERGY STAR defines a heat pump's coefficient of performance (COP) as the ratio of space heating delivered to electrical energy consumed, a dimensionless quantity. EIA lists one kilowatt-hour as 3,412 Btu, so HSPF2 divided by 3.412 puts the seasonal rating in the same terms. Treat it as a rough seasonal equivalent: a tested COP is measured at a single set of conditions, such as 5°F.
What the estimate leaves out
- HSPF2 is a seasonal rating for a reference climate: the FTC's labeling rule says it is calculated for heating Region IV. Real cold-weather performance varies.
- The result excludes maintenance, standby losses and fixed monthly utility charges, and does not add backup heat for your climate.
- The default electricity price is a statewide average for July 2026, and the default gas prices are 2025 statewide averages. Your utility's rate, and its winter rate, may differ. EIA says the heat content of natural gas may vary by location and over time.